Power Monitoring and Management 291Viewing the Health Status of the PowerSupply UnitsThe Power Supplies page displays the status and rating of the power supplyunits installed in the server.Using the Web-Based InterfaceTo view the health status of the power supply units:1 Log in to the iDRAC6 Web-based interface.2 Select Power Supplies in the system tree. The Power Supplies pagedisplays and provides the following information:• Power Supplies Redundancy Status: The possible values are:– Full: The power supplies installed in the system are of the same typeand they are functioning properly.– Lost: In systems with two power supply units, the power suppliesinstalled in the system are of different types or one of them ismalfunctioning or removed. In systems with four power supply units,the power supplies installed in the system are of different types, or twoor three units are malfunctioning or removed.– Disabled: Only one of the power supplies is available. No redundancyexists.– Degraded (only in systems with four power supply units): Four powersupply units are installed in the system but one of them ismalfunctioning or removed.• Individual Power Supply Elements: The possible values are:– Status displays the following:• OK indicates that the power supply unit is present andcommunicating with the server.• Warning indicates that only warning alerts have been issuedand corrective action must be taken by the administrator. Ifcorrective actions are not taken, it could lead to critical or severepower failures that can affect the integrity of the server.