Script Commands 231NOTE: When all firmware downloads have successfully completed, this commandreturns a Successful status. If any firmware downloads fail, this command showsthe firmware download status of each targeted physical disk. This command returnsthe status values shown in the following table.Show RAID Controller ModuleFor each RAID controller module in a storage array, this command returns thefollowing information:• Status (Online, Offline)• Current firmware and NVSRAM configuration• Pending firmware and NVSRAM configuration configurations (if any)• Board ID• Product ID• Product revision• Serial number• Date of manufacture• Date and time to which the RAID controller module is set• Associated virtual disks (including preferred owner)• Ethernet port• Physical disk interfaceSyntaxshow (allControllers | controller [(0 | 1)])[summary]Status DefinitionSuccessful Downloads completed without errors.Not Attempted Downloads did not start.Partial Download Downloads are in progress.Failed Downloads completed with errors.