C-4 Dell Workstation Midsize Systems User’s GuideThe ICU detectsa resource conflictbetween this card andconflicting_card. Theconflicting resourcewas:resource.You added or modified acard that now requiresaresource valuealready in use byconflicting_card.Try each of the following options until the prob-lem is resolved:• Modify the card you are adding so that it usesa different value for resource. See “Modify-ing a Card” in Chapter 4 for instructions.• Modifyconflicting_card so that it usesa different value for resource. See “Modify-ing a Card” in Chapter 4 for instructions.• Ifconflicting_card is not the systemboard or riser board, remove it from the com-puter. See “Removing a Card” in Chapter 4for instructions.• Remove all expansion cards from the ICU,and then add them back one at a time, begin-ning with the new card and resolvingresource conflicts as they arise. See “Remov-ing a Card” and “Adding a Listed Card” or“Adding an Unlisted Card” in Chapter 4 forinstructions.• If you cannot resolve the resource conflict byany of the preceding methods, remove thenew card. If you were modifying an existingcard, reset the modified card to its previousresource value.Table C-1. Configuration Utility Messages (continued)Message Probable Cause Corrective ActionNOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.