Restoring the Factory Default SettingsRestoring the factory-default settings deletes the existing NVRAM settings, startup configuration, and allconfigured settings such as, stacking or fanout.Z9000MXL SwitchTo restore the factory default settings, use the restore factory-defaults stack-unit {0-5 |all} {clear-all | nvram} command in EXEC Privilege mode.CAUTION: There is no undo for this command.Important Points to Remember• When you restore all the units in a stack, these units are placed in standalone mode.• When you restore a single unit in a stack, only that unit is placed in standalone mode. No other unitsin the stack are affected.• When you restore the units in standalone mode, the units remain in standalone mode after therestoration.• After the restore is complete, the units power cycle immediately.The following example illustrates the restore factory-defaults command to restore the factory defaultsettings.Dell#restore factory-defaults stack-unit 0 nvram************************************************************************ Warning - Restoring factory defaults will delete the existing ** persistent settings (stacking, fanout, etc.) ** After restoration the unit(s) will be powercycled immediately. ** Proceed with caution ! ************************************************************************Proceed with factory settings? Confirm [yes/no]:yes-- Restore status --Unit Nvram Config------------------------0 SuccessPower-cycling the unit(s).....Management 73