AccessoriesThese accessories are available. Contact your Eatonrepresentative for additional information.Low voltage closingThe Low Voltage Closing Accessory utilizes 120 or 240VAC for closing power (Figures 22, 23, and 24). Multiplelow voltage closing accessories are available for reclosersequipped with low voltage closing. The low voltage closingaccessories available for the Form 4D recloser controlinclude the appropriate receptacles and wiring based uponthe input supply voltage. Table 6 lists the available lowvoltage closing input/output receptacles and cables for theForm 4D pole-mount recloser control.Cabinet ordering accessories●● AISI 304 stainless steel cabinet construction.Incoming power receptaclesThe Incoming Power Receptacle allows the user toconveniently plug the power cable into the control,eliminating the need for hardwiring to the control. Variousoptions are available based upon the input power voltage,and phase sensing requirements. Table 6 includes theavailable input receptacles and cables for the Form 4Dpole-mount recloser control.Internal voltage sensingA four-wire cable and input receptacle accessory(Table 7) is required for Type NOVA three-phase recloserswith the internal voltage sensing (IVS) option. Internalvoltage sensors, located on the source side, indicate voltagemagnitude within an accuracy 2% or better and a phasedegree accuracy within 1.5 degrees (includes sensor, cable,and control). The 4-pin receptacle accessory is pre-wired tothe voltage inputs on the control. Refer to Service InstructionsS280-42-1 NOVA Three-Phase Recloser Installation andOperation Instructions for additional setting information.Table 6. Receptacles and wiring; input and low voltage closing cables*Description Catalog number120 VAC low-voltage closing 2-pin input and 2-pin output receptacles KME4D-1775-A120 VAC low-voltage closing with 3-pin input and 2-pin output receptacles KME4D-1775-B120 VAC low-voltage closing with inlet hole and 2-pin output receptacle KME4D-1775-C240 VAC low-voltage closing with 2-pin input and 2-pin output receptacle KME4D-1775-D240 VAC low-voltage closing with 3-pin input and 2-pin output receptacle KME4D-1775-E240 VAC low voltage closing, for 2-wire with inlet hole and 2-pin output receptacle KME4D-1775-F240 VAC low-voltage closing, for 3-wire with inlet hole and 2-pin output receptacle KME4D-1775-G120 VAC or 240 VAC input receptacle, 2-pin KME4D-1775-H120 VAC input receptacle, 3-pin KME4D-1775-J240 VAC input receptacle, 3-pin KME4D-1775-KAC Input Cable, 120 or 240 VAC, 2-wire for 2-pin input for use with KME4D-1775-A, KME4D-1775-D, or KME4D-1775-Hreceptacles. Replace X with desired length. Select from 10 to 80 feet.KA11ME1-XAC Input Cable, 240 VAC, 3-wire for 3-pin input for use with KME4D-1775-E or KME4D-1775-K receptacles. Replace X withdesired length. Select from 10 to 80 feet.KME4-67-2-XAC Input Cable, 120 VAC, 3-wire for 3-pin input for use with KME4D-1775-B and KME4D-1775-J receptacles. Replace X withdesired length. Select from 10 to 80 feet.KME4-67-3-XLow Voltage Closing Cable, 2-wire for use with KME4D-1775-A, KME4D-1775-B, KME4D-1775-C, KME4D-1775-D, KME4D-1775-E,KME4D-1775-F, and KME4D-1775-G low voltage closing receptacles. Replace X with desired length. Select from 10 to 80 feet.KA13ME1-X*Low-voltage closing receptacles are only applicable to Eaton’s Cooper Power series auxiliary and line-powered reclosers with 14-pin connection (WE,WVE27,WVE38X, VWE, VWVE27, VWVE38X, VSA12, VSA12B, VSA16, VSA20, VSA20A, VSO12, VSO16, NOVA15, NOVA27, NOVA38).Table 7. Internal voltage sensingDescription Catalog numberInternal voltage sensing input receptacle, 4-pin KME4D-3799-Aotee:N Internal voltage sensing receptacle is only compatiblewith reclosers equipped with internal voltage sensors.otee:N The internal voltage sensing cable (KA97ME) isordered with the recloser. If a replacement cable isrequired, contact your Eaton representative.28 operation inStrUCtionS MN280049EN September 2017Form 4D Microprocessor-based pole-mount recloser control installation and operation instructions