2 Engineering2.13 External brake76 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.comTable 12: Advanced Mode (Advanced Mode): P3-01 = 1Mechanical brake (actuation) for RAMO5The brake is switched off with the stop command according to the decelera-tion time.The brake is released with the Start command.The delay is set using parameters P3-04 and P3-05.Table 13: Parameters for brake for RAMO5Control commands Action of the driveStart signal Enable device→ The frequency increases to the value set in P3-02.→ The current and/or torque are monitored until they reach the level set in P3-04.→ The brake is released.→ The output frequency remains at the value set in P3-02 for the time (delay) set inP3-05.→ The ramps are on the set point. The drive continues the ramp up to the setpoint value.Normal operation - drive is runningStop order The frequency drops and the brake is applied when the output frequency falls below thevalue set in P3-03.→ The drive continues the ramp to a standstill.→ The output of the drive is disabled.Para-meterDesignation Description UnitP3-04 Brake Release Delay Determines the time before the mechanical brake isreleased.sP3-05 Brake Apply Delay Determines the time between the signal to close themechanical brake and the drive being disconnected.s