Serial Interface OperationEaton ePDU G3 Operation Manual P-164000277—Rev 1 www.eaton.com/ePDU 82PDU.OutletSystem.Outlet[x].AutomaticRestart Parameter 0 : not restart at device startup1 : should sequence back ON in line withPDU.Outlet[u].RestartTimer2 : should take the state the outlet had when power waslost.If the state was ON, should sequence back ON in line withthe outlet RestartTimer.- RWPDU.OutletSystem.Outlet[x].ChangedStatus.OverCurrent Timestamp s ROPDU.OutletSystem.Outlet[x].ConfigCurrent Constant Nominal Amps: 10A, 15A, 16A, 20A, .. mA ROPDU.OutletSystem.Outlet[x].Current Measure Current Measurement mA ROPDU.OutletSystem.Outlet[x].DelayBeforeShutdown Command 0-n: Delayed shutoff-1: Cancel / No actionWhen read, returns the downcount.s RWPDU.OutletSystem.Outlet[x].DelayBeforeStartup Command 0-n: Delayed restart-1: Cancel / No actionWhen read, returns the downcount.s RWPDU.OutletSystem.Outlet[x].EWEntity.Importance Parameter Energy Wise Importance - RWPDU.OutletSystem.Outlet[x].EWEntity.Keyword String[31] Energy Wise Keyword - RWPDU.OutletSystem.Outlet[x].EWEntity.Level Parameter Energy Wise Level - RWPDU.OutletSystem.Outlet[x].EWEntity.Role String[31] Energy Wise Role - RWPDU.OutletSystem.Outlet[x].GangID Constant Breaker/section index where the Outlet is connected.It is the x of Gang[x] collection.- ROPDU.OutletSystem.Outlet[x].iName String[31] Outlet friendly name. - RWPDU.OutletSystem.Outlet[x].OutletID Constant Numbering of the outlet into the breaker/section module. 1 to 56.- ROPDU.OutletSystem.Outlet[x].OverCurrent[1].Threshold Parameter Threshold mA RWPDU.OutletSystem.Outlet[x].OverCurrent[3].Threshold Parameter Threshold mA RWPDU.OutletSystem.Outlet[x].OverCurrent[4].Threshold Parameter Threshold mA RWPDU.OutletSystem.Outlet[x].PeakFactor Measure Crest factor of the current that is provided by the outlet. m% ROPDU.OutletSystem.Outlet[x].PhaseID Constant Phase ID that powers the outlet:- 1, 2, 3 to identify a simple phase.- 12, 23, 31 to identify a composed phase.- ROPDU.OutletSystem.Outlet[x].PoleID Constant Pole ID of the breaker/section where the Outlet isconnected. Two cases are:- Section or Single pole breaker, always 0.- Double pole breaker:0: when powered between 2 poles1: when powered by pole 1 voltage.2: when powered by pole 2 voltage.- ROPDU.OutletSystem.Outlet[x].PowerFactor Measure Power factor of the current provided by the phase.Value 0 to 100 for Cos PHI = 0.00 to 1.00m% ROTable 8. ePDU CLI Objects (Continued)XML Object Name Type Description Unit Access