GE Multilin D30 Line Distance Relay B-37APPENDIX B B.4 MEMORY MAPPINGBA70A ...Repeated for Non-Volatile Latch 2A714 ...Repeated for Non-Volatile Latch 3A71E ...Repeated for Non-Volatile Latch 4A728 ...Repeated for Non-Volatile Latch 5A732 ...Repeated for Non-Volatile Latch 6A73C ...Repeated for Non-Volatile Latch 7A746 ...Repeated for Non-Volatile Latch 8A750 ...Repeated for Non-Volatile Latch 9A75A ...Repeated for Non-Volatile Latch 10A764 ...Repeated for Non-Volatile Latch 11A76E ...Repeated for Non-Volatile Latch 12A778 ...Repeated for Non-Volatile Latch 13A782 ...Repeated for Non-Volatile Latch 14A78C ...Repeated for Non-Volatile Latch 15A796 ...Repeated for Non-Volatile Latch 16Digital Counter (Read/Write Setting) (8 modules)A800 Digital Counter 1 Function 0 to 1 --- 1 F102 0 (Disabled)A801 Digital Counter 1 Name --- --- --- F205 “Counter 1"A807 Digital Counter 1 Units --- --- --- F206 (none)A80A Digital Counter 1 Block 0 to 65535 --- 1 F300 0A80B Digital Counter 1 Up 0 to 65535 --- 1 F300 0A80C Digital Counter 1 Down 0 to 65535 --- 1 F300 0A80D Digital Counter 1 Preset –2147483647 to2147483647 --- 1 F004 0A80F Digital Counter 1 Compare –2147483647 to2147483647--- 1 F004 0A811 Digital Counter 1 Reset 0 to 65535 --- 1 F300 0A812 Digital Counter 1 Freeze/Reset 0 to 65535 --- 1 F300 0A813 Digital Counter 1 Freeze/Count 0 to 65535 --- 1 F300 0A814 Digital Counter 1 Set To Preset 0 to 65535 --- 1 F300 0A815 Reserved (11 items) --- --- --- F001 0A820 ...Repeated for Digital Counter 2A840 ...Repeated for Digital Counter 3A860 ...Repeated for Digital Counter 4A880 ...Repeated for Digital Counter 5A8A0 ...Repeated for Digital Counter 6A8C0 ...Repeated for Digital Counter 7A8E0 ...Repeated for Digital Counter 8IEC 61850 received analog settings (read/write)AA00 IEC 61850 GOOSE analog 1 default value –1000000 to 1000000 --- 0.001 F060 1000AA02 IEC 61850 GOOSE analog input 1 mode 0 to 1 --- 1 F491 0 (Default Value)AA03 IEC 61850 GOOSE analog input 1 units --- --- --- F207 (none)AA05 IEC 61850 GOOSE analog input 1 per-unit base 0 to 999999999.999 --- 0.001 F060 1AA07 ...Repeated for IEC 61850 GOOSE analog input 2AA0E ...Repeated for IEC 61850 GOOSE analog input 3AA15 ...Repeated for IEC 61850 GOOSE analog input 4AA1C ...Repeated for IEC 61850 GOOSE analog input 5AA23 ...Repeated for IEC 61850 GOOSE analog input 6AA2A ...Repeated for IEC 61850 GOOSE analog input 7AA31 ...Repeated for IEC 61850 GOOSE analog input 8AA38 ...Repeated for IEC 61850 GOOSE analog input 9AA3F ...Repeated for IEC 61850 GOOSE analog input 10AA46 ...Repeated for IEC 61850 GOOSE analog input 11AA4D ...Repeated for IEC 61850 GOOSE analog input 12AA54 ...Repeated for IEC 61850 GOOSE analog input 13Table B–9: MODBUS MEMORY MAP (Sheet 30 of 46)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT