B-52 D30 Line Distance Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BBAA23 ...Repeated for IEC 61850 GOOSE Analog Input 6AA2A ...Repeated for IEC 61850 GOOSE Analog Input 7AA31 ...Repeated for IEC 61850 GOOSE Analog Input 8AA38 ...Repeated for IEC 61850 GOOSE Analog Input 9AA3F ...Repeated for IEC 61850 GOOSE Analog Input 10AA46 ...Repeated for IEC 61850 GOOSE Analog Input 11AA4D ...Repeated for IEC 61850 GOOSE Analog Input 12AA54 ...Repeated for IEC 61850 GOOSE Analog Input 13AA5B ...Repeated for IEC 61850 GOOSE Analog Input 14AA62 ...Repeated for IEC 61850 GOOSE Analog Input 15AA69 ...Repeated for IEC 61850 GOOSE Analog Input 16AA70 ...Repeated for IEC 61850 GOOSE Analog Input 17AA77 ...Repeated for IEC 61850 GOOSE Analog Input 18AA7E ...Repeated for IEC 61850 GOOSE Analog Input 19AA85 ...Repeated for IEC 61850 GOOSE Analog Input 20AA8C ...Repeated for IEC 61850 GOOSE Analog Input 21AA93 ...Repeated for IEC 61850 GOOSE Analog Input 22AA9A ...Repeated for IEC 61850 GOOSE Analog Input 23AAA1 ...Repeated for IEC 61850 GOOSE Analog Input 24AAA8 ...Repeated for IEC 61850 GOOSE Analog Input 25AAAF ...Repeated for IEC 61850 GOOSE Analog Input 26AAB6 ...Repeated for IEC 61850 GOOSE Analog Input 27AABD ...Repeated for IEC 61850 GOOSE Analog Input 28AAC4 ...Repeated for IEC 61850 GOOSE Analog Input 29AACB ...Repeated for IEC 61850 GOOSE Analog Input 30AAD2 ...Repeated for IEC 61850 GOOSE Analog Input 31AAD9 ...Repeated for IEC 61850 GOOSE Analog Input 32IEC 61850 XCBR Configuration (Read/Write Settings and Commands) (6 modules)AB00 Operand for IEC 61850 XCBR1.ST.Loc status 0 to 4294967295 --- 1 F300 0AB02 Command to Clear XCBR1 OpCnt (Operation Counter 0 to 1 --- 1 F126 0 (No)AB03 Operand for IEC 61850 XCBR Check Sync Release 0 to 4294967295 --- 1 F300 0AB05 Operand for IEC 61850 XCBR Open Interlock 0 to 4294967295 --- 1 F300 0AB07 Operand for IEC 61850 XCBR Close Interlock 0 to 4294967295 --- 1 F300 0AB09 Operand for IEC 61850 XCBR Pos ct1Model 0 to 4 --- 1 F001 2AB0A Operand for IEC 61850 XCBR Pos sboTimeout 2 to 60 s 1 F001 30AB0B ...Repeated for Module 2AB16 ...Repeated for Module 3AB21 ...Repeated for Module 4AB2C ...Repeated for Module 5AB37 ...Repeated for Module 6IEC 61850 LN Name Prefixes (Read/Write Settings)AB48 IEC 61850 Logical Node LPHD1 Name Prefix 0 to 65534 --- 1 F206 (none)AB4B IEC 61850 Logical Node PIOCx Name Prefix (72 items) 0 to 65534 --- 1 F206 (none)AC23 IEC 61850 Logical Node PTOCx Name Prefix (24 items) 0 to 65534 --- 1 F206 (none)AC6B IEC 61850 Logical Node PTUVx Name Prefix (13 items) 0 to 65534 --- 1 F206 (none)AC92 IEC 61850 Logical Node PTOVx Name Prefix (10 items) 0 to 65534 --- 1 F206 (none)ACB6 IEC 61850 Logical Node PDISx Name Prefix (10 items) 0 to 65534 --- 1 F206 (none)ACD4 IEC 61850 Logical Node RBRFx Name Prefix (24 items) 0 to 65534 --- 1 F206 (none)AD1C IEC 61850 Logical Node RPSBx Name Prefix 0 to 65534 --- 1 F206 (none)AD1F IEC 61850 Logical Node RRECx Name Prefix (6 items) 0 to 65534 --- 1 F206 (none)AD31 IEC 61850 Logical Node MMXUx Name Prefix (6 items) 0 to 65534 --- 1 F206 (none)AD43 IEC 61850 Logical Node GGIOx Name Prefix (5 items) 0 to 65534 --- 1 F206 (none)AD52 IEC 61850 Logical Node RFLOx Name Prefix (5 items) 0 to 65534 --- 1 F206 (none)Table B–10: MODBUS MEMORY MAP (Sheet 44 of 62)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT