GE Multilin F60 Feeder Management Relay E-7APPENDIX E E.1 DEVICE PROFILE DOCUMENTE34cont’d2 32-bit Analog Input Reporting Deadband 1 (read) 00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)2 (write) 00, 01 (start-stop)07, 08 (limited quantity)17, 28 (index)3 Short floating point Analog Input ReportingDeadband1 (read) 00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)50 0 Time and Date 1 (read) 00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)1 Time and Date(default – see Note 1)1 (read)2 (write)00, 01 (start-stop)06 (no range, or all)07 (limited qty=1)08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)52 2 Time Delay Fine 129 (response) 07 (limited quantity)(quantity = 1)60 0 Class 0, 1, 2, and 3 Data 1 (read)20 (enable unsol)21 (disable unsol)22 (assign class)06 (no range, or all)1 Class 0 Data 1 (read)22 (assign class)06 (no range, or all)2 Class 1 Data 1 (read)20 (enable unsol)21 (disable unsol)22 (assign class)06 (no range, or all)07, 08 (limited quantity)3 Class 2 Data4 Class 3 Data70 1 File identifier 2 (write) 1b (free format) 129 (response) 1b (free format)3 File command 25 (open)27 (delete)5b (free format)4 File command status 1 (read)22 (assign class)26 (close)30 (abort)06 (no range, or all)07, 08 (limited quantity)5b (free format)129 (response)130 (unsol. resp.)5b (free format)5 File transfer 1 (read)2 (write)22 (assign class)06 (no range, or all)07, 08 (limited quantity)5b (free format)129 (response)130 (unsol. resp.)5b (free format)6 File transfer status 1 (read)22 (assign class)06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)5b (free format)7 File descriptor 1 (read)22 (assign class)28 (get file info.)06 (no range, or all)07, 08 (limited quantity)5b (free format)129 (response)130 (unsol. resp.)5b (free format)80 1 Internal Indications 2 (write) 00 (start-stop)(index must =7)--- No Object (function code only)see Note 313 (cold restart)--- No Object (function code only) 14 (warm restart)--- No Object (function code only) 23 (delay meas.)Table E–2: IMPLEMENTATION TABLE (Sheet 4 of 4)OBJECT REQUEST RESPONSEOBJECTNO. VARIATIONNO. DESCRIPTION FUNCTIONCODES (DEC) QUALIFIERCODES (HEX) FUNCTIONCODES (DEC) QUALIFIERCODES (HEX)Note 1: A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default varia-tions for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. Refer to the Communications section in Chapter 5for details. This optimizes the class 0 poll data size.Note 2: For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-event objects, qualifiers 17 or 28 are always responded.)Note 3: Cold restarts are implemented the same as warm restarts – the F60 is not restarted, but the DNP process is restarted.