GE Multilin F60 Feeder Protection System B-11APPENDIX B B.4 MEMORY MAPPINGBUser Displays Actuals (Read Only)1080 Formatted user-definable displays (16 items) --- --- --- F200 (none)Modbus User Map Actuals (Read Only)1200 User Map Values (256 items) 0 to 65535 --- 1 F001 0Element Targets (Read Only)14C0 Target Sequence 0 to 65535 --- 1 F001 014C1 Number of Targets 0 to 65535 --- 1 F001 0Element Targets (Read/Write)14C2 Target to Read 0 to 65535 --- 1 F001 0Element Targets (Read Only)14C3 Target Message --- --- --- F200 “.”Digital Input/Output States (Read Only)1500 Contact Input States (6 items) 0 to 65535 --- 1 F500 01508 Virtual Input States (8 items) 0 to 65535 --- 1 F500 01510 Contact Output States (4 items) 0 to 65535 --- 1 F500 01518 Contact Output Current States (4 items) 0 to 65535 --- 1 F500 01520 Contact Output Voltage States (4 items) 0 to 65535 --- 1 F500 01528 Virtual Output States (6 items) 0 to 65535 --- 1 F500 01530 Contact Output Detectors (4 items) 0 to 65535 --- 1 F500 0Remote Input/Output States (Read Only)1540 Remote Device States 0 to 65535 --- 1 F500 01542 Remote Input States (4 items) 0 to 65535 --- 1 F500 01550 Remote Devices Online 0 to 1 --- 1 F126 0 (No)Platform Direct Input/Output States (Read Only)15C0 Direct input states (6 items) 0 to 65535 --- 1 F500 015C8 Direct outputs average message return time 1 0 to 65535 ms 1 F001 015C9 Direct outputs average message return time 2 0 to 65535 ms 1 F001 015CA Direct inputs/outputs unreturned message count - Ch. 1 0 to 65535 --- 1 F001 015CB Direct inputs/outputs unreturned message count - Ch. 2 0 to 65535 --- 1 F001 015D0 Direct device states 0 to 65535 --- 1 F500 015D1 Reserved 0 to 65535 --- 1 F001 015D2 Direct inputs/outputs CRC fail count 1 0 to 65535 --- 1 F001 015D3 Direct inputs/outputs CRC fail count 2 0 to 65535 --- 1 F001 0Ethernet Fibre Channel Status (Read/Write)1610 Ethernet primary fibre channel status 0 to 2 --- 1 F134 0 (Fail)1611 Ethernet secondary fibre channel status 0 to 2 --- 1 F134 0 (Fail)Data Logger Actuals (Read Only)1618 Data logger channel count 0 to 16 channel 1 F001 01619 Time of oldest available samples 0 to 4294967295 seconds 1 F050 0161B Time of newest available samples 0 to 4294967295 seconds 1 F050 0161D Data logger duration 0 to 999.9 days 0.1 F001 0Sensitive Directional Power Actuals (Read Only) (2 modules)1680 Sensitive Directional Power 1 Power -2147483647 to 2147483647 W 1 F060 01682 Sensitive Directional Power 2 Power -2147483647 to 2147483647 W 1 F060 0Frequency Rate of Change Actuals (Read Only) (4 modules)16E0 Frequency Rate of Change 1 -327.67 to 327.67 Hz/s 0.01 F002 016E1 Reserved (3 items) 0 to 65535 --- 1 F001 016E4 ...Repeated for Frequency Rate of Change 216E8 ...Repeated for Frequency Rate of Change 316EC ...Repeated for Frequency Rate of Change 4Source Current (Read Only) (6 modules)1800 Source 1 Phase A Current RMS 0 to 999999.999 A 0.001 F060 01802 Source 1 Phase B Current RMS 0 to 999999.999 A 0.001 F060 01804 Source 1 Phase C Current RMS 0 to 999999.999 A 0.001 F060 0Table B–9: MODBUS MEMORY MAP (Sheet 3 of 53)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT