B-60 L60 Line Phase Comparison System GE MultilinB.4 MEMORY MAPPING APPENDIX BBDirect Inputs/Outputs (Read/Write Setting)C880 Direct Device ID 1 to 16 --- 1 F001 1C881 Direct I/O Channel 1 Ring Configuration Function 0 to 1 --- 1 F126 0 (No)C882 Platform Direct I/O Data Rate 64 to 128 kbps 64 F001 64C883 Direct I/O Channel 2 Ring Configuration Function 0 to 1 --- 1 F126 0 (No)C884 Platform Direct I/O Crossover Function 0 to 1 --- 1 F102 0 (Disabled)Direct Input/Output Commands (Read/Write Command)C888 Direct Input/Output Clear Counters Command 0 to 1 --- 1 F126 0 (No)Direct Inputs (Read/Write Setting) (32 modules)C890 Direct Input 1 Device Number 0 to 16 --- 1 F001 0C891 Direct Input 1 Number 0 to 96 --- 1 F001 0C892 Direct Input 1 Default State 0 to 3 --- 1 F086 0 (Off)C893 Direct Input 1 Events 0 to 1 --- 1 F102 0 (Disabled)C894 ...Repeated for Direct Input 2C898 ...Repeated for Direct Input 3C89C ...Repeated for Direct Input 4C8A0 ...Repeated for Direct Input 5C8A4 ...Repeated for Direct Input 6C8A8 ...Repeated for Direct Input 7C8AC ...Repeated for Direct Input 8C8B0 ...Repeated for Direct Input 9C8B4 ...Repeated for Direct Input 10C8B8 ...Repeated for Direct Input 11C8BC ...Repeated for Direct Input 12C8C0 ...Repeated for Direct Input 13C8C4 ...Repeated for Direct Input 14C8C8 ...Repeated for Direct Input 15C8CC ...Repeated for Direct Input 16C8D0 ...Repeated for Direct Input 17C8D4 ...Repeated for Direct Input 18C8D8 ...Repeated for Direct Input 19C8DC ...Repeated for Direct Input 20C8E0 ...Repeated for Direct Input 21C8E4 ...Repeated for Direct Input 22C8E8 ...Repeated for Direct Input 23C8EC ...Repeated for Direct Input 24C8F0 ...Repeated for Direct Input 25C8F4 ...Repeated for Direct Input 26C8F8 ...Repeated for Direct Input 27C8FC ...Repeated for Direct Input 28C900 ...Repeated for Direct Input 29C904 ...Repeated for Direct Input 30C908 ...Repeated for Direct Input 31C90C ...Repeated for Direct Input 32Direct Input/Output Alarms (Read/Write Setting)CAD0 Direct Input/Output Channel 1 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD1 Direct Input/Output Channel 1 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CAD2 Direct Input/Output Channel 1 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CAD3 Direct Input/Output Channel 1 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CAD4 Reserved (4 items) 1 to 1000 --- 1 F001 10CAD8 Direct Input/Output Channel 2 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD9 Direct Input/Output Channel 2 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CADA Direct Input/Output Channel 2 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CADB Direct Input/Output Channel 2 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)Table B–10: MODBUS MEMORY MAP (Sheet 52 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT