P44x/EN PL/Hb6 Programmable Logic(PL) 6-46 MiCOM 40 Agile P442, P444Ordinal English Text Description Source778 LED 8 Red Condit Hardware version K - Assignment of signal to driveoutput LED 8 redPSL657 LED 9 Grn Hardware version K - Programmable Green LED n° 9 SW656 LED 9 Red Hardware version K - Programmable Red LED n° 9 SW656 LED Cond IN 1 Hardware version J - Assignment of signal to driveoutput Function Key LED 1PSL657 LED Cond IN 2 Hardware version J - Assignment of signal to driveoutput Function Key LED 2PSL658 LED Cond IN 3 Hardware version J - Assignment of signal to driveoutput Function Key LED 3PSL659 LED Cond IN 4 Hardware version J - Assignment of signal to driveoutput Function Key LED 4PSL660 LED Cond IN 5 Hardware version J - Assignment of signal to driveoutput Function Key LED 5PSL661 LED Cond IN 6 Hardware version J - Assignment of signal to driveoutput Function Key LED 6PSL662 LED Cond IN 7 Hardware version J - Assignment of signal to driveoutput Function Key LED 6PSL663 LED Cond IN 8 Hardware version J - Assignment of signal to driveoutput Function Key LED 7PSL1672 to1677LN1 Analog Alarm toLN6 Analog AlarmRelays with IEC 61850 9-2 Ethernet board only(software version D5.x)If two consecutive of any Logical Node frames havenot been received within the Merge Unit Delay setparameter (time of silence in the reception of theframe), the LN is “absent”PSL1688 to1693LN1 Async toLN6 AsyncRelays with IEC 61850 9-2 Ethernet board only(software version D5.x)Any Logical Node is synchronized with Internal (local)synchronizationPSL1680 to1685LN1 Test Mode toLN6 Test ModeRelays with IEC 61850 9-2 Ethernet board only(software version D5.x)Any Logical Node is in “Test Mode”PSL1704 to1709LN1 Val Fail toLN6 Val FailRelays with IEC 61850 9-2 Ethernet board only(software version D5.x)The sample value (SV) transmitted status from the LNis “failed”PSL1696 to1701LN1 Val Quest toLN6 Val QuestRelays with IEC 61850 9-2 Ethernet board only(software version D5.x)The sample value (SV) transmitted status from the LNis “questionable”PSL188 Lockout Alarm Lockout alarm: An alarm is issued with: ‘Man CBUnhealthy’or no 'Check Sync OK' (CB conditioning) or‘Man CB Cls Fail’ or ‘Man CB Fail Trip’ or 'F.F. Lock' or'CB Op Time Lock' or 'CB Ops Lockout'PSL (OUT)331 Loss. Load Trip Loss of load trip (in application without communicationscheme and a 3P Trip logic)PSL (OUT)Loss of load191 Man CB Cls Fail Alarm CB fail for manual closing command PSL (OUT)190 Man CB Trip Fail Alarm CB Fail for manual trip command PSL (OUT)192 Man CB Unhealthy Alarm CB performed by unhealthy condition PSL (OUT)