14WI1089 GEM-P801 Installation Instructionsindicated at the keypad. The Supervisorytimer is programmable from 1-8 hours; 0means NO supervision. Note: If ULHousehold Fire is enabled, the WirelessSmoke Supervisory Timer will automaticallybe sey to 4 hours.[18]Test Timer OffsetEnter the time, in hours, that a Test Timerwill be reported after Dealer Mode has beenexited. With the default value of 12, the testtimer will be sent 12 hours after exitingDealer Mode. The test timer can also beoffset using PCD-Windows DownloadingSoftware. On power up the test timer is sentimmediately. Follow the commands below tooffset the test timer using QuickloaderSoftware:1 From the Status Screen, selectMiscellaneous2 Enter the number of hours for TestTimer Offset3 Select Set Test Timer Offset4 Select OKSystem Features[20]Keypad Features 1(1) Enable Keypad Fire (7G )Additional Programming required:Select reporting to Telco 1 [36-1] or Telco 3[56-1].(2) Enable Keypad AUX (8G )Additional Programming required:Select reporting to Telco 1 [36-2] or Telco 3[56-2].(3) Enable Keypad Panic (9G )Additional Programming required:Select reporting to Telco 1 [36-3] or Telco 3[56-3].(4) Enable Ambush - If enabled, the 8thUser Code will send an Ambush reportwhen entered to disarm the system.Additional Programming required:Program User 8 Arm/Disarm Code.Select reporting to Telco 1 [36-2] or Telco 3[56-2].UL Installations: If Keypad Fire [20-1] isenabled, the keypad must be mountedwithin (3) three feet from the Control Panel.[21]Keypad Features 2(1) Audible Panic - Keypad Panic will notturn the Bell on unless this option isprogrammed.(2) Exit/Entry with Urgency - select to givean audible indication of Exit and Entrytimes. During the last 10 seconds of entryand exit time, the keypad sounds a distinctsound to indicate the premises must be leftor the panel must be disarmed.(3) Display Bypassed (Armed) - Select todisplay bypassed zones while the panel isarmed.(4) Disable Code Entry Beeps - Programto disable keypad beeping on valid codeand function entries.[22]Miscellaneous Features 1(1) Abort Delay - Program to allow a 15second Delay (except 24 Hour Zones) aftera zone trip before reporting. Disarm thesystem within 15 seconds to preventreporting.(2) Easy Exit/Easy Arm- EnablesA0 command. While the system isarmed, entering this command allows 3minutes to Exit through Exit/Entry and Exit/Entry Follower Zones. Enabling this optionalso enables Easy Arm, press the D key toarm the system.(3) Swinger Shutdown - Automaticallydisables armed zones with excessive alarm/restores (swingers). Non-24-Hour Protectionzones: allows only 3 alarms and 2 restoresper zone per arming before the zone isdisabled.(4) Bell on Line Cut (Armed) - Program toturn the Bell Output on if the telephone linehas been cut while the panel is armed.[23]Programmable Output Features 1(1) Audio Verification - Program to activatethe PGM during reporting. Select specificzones for audio verification by programmingthe required zones in PGM Output [08],PGM Features 2 [24] and PGM Features 3[25]. Connect the PGM to the Veriphone TMtrigger low input.(2) Access Output - Activates the PGM