24WI1089 GEM-P801 Installation InstructionsSystem TroublesKeypad Beeps orjSYSTEMFlashesZone LEDONSystem TroubleConditionCause/Action1 Beep 1 AC Power Failure This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source.2 Low Battery If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If thetrouble does not go away in 24 hours, replace the battery.3 Communication Failure /PCPreset Fail / Line FailThe system was not able to report to central station. Check panel programming and telephone line wiring. The trouble will clear afterit has been acknowledged by viewing the system trouble as long as the telephone line has passed a line cut test (tested automaticallyby the panel). The Panel did not successfully connect and download/upload with the computer running PCPreset - check AutoDownload ID number, Callback Number or PCPreset Setup.4 Telephone Line Cut The telephone line has failed. If telephone service has been temporarily interrupted, the trouble will clear when restored andacknowledged by viewing the system trouble.2 Beeps 1 Bell/Siren line Cut There is a problem with the Bell or Siren wiring. EOL2.2K resistor must be installed.2 2-wire Fire Trouble There is a problem with the wiring of the Fire Zone.3 Rcvr Fail-to-Respond/RcvrTamperThe receiver is not responding to the panel. The red LED on the receiver should be flashing, refer to WI850. The cover is off thereceiver causing a tamper signal to be transmitted.4 Receiver Jam A signal is blocking the normal reception of transmissions from the wireless devices. Ensure that the green LED on the receiver is noton continuously, refer to receiver manual WI850.3 Beeps 1-6 WirelessTransmitter Low BatteryThe battery in the wireless transmitter is low and should be replaced. This transmitter is on the zone corresponding to the number ofthe zone light flashing. The replacement battery for the GEM Trans2 door/window transmitter and the GEM PIR wireless motiondetector is the Duracell DL123A. (2 required for the GEM-PIR) WARNING: Replace batteries only with the same type as specifiedabove. Use of another battery may present a risk of fire or explosion. Do not recharge or disassemble battery or dispose of in fire.4 Beeps 1-6 WirelessTransmitterSupervisory FailureThe panel has not received a supervisory signal from the transmitter within the time programmed. Check Wireless Supervisory Timer[16] Programming. Check the placement of the transmitter and receiver, refer to WI850.5 Beeps 1-4 Wireless Smoke DetectorLow BatteryThe battery in the wireless smoke detector is low and should be replaced. This wireless smoke detector should be marked with anumber corresponding to the number of the zone light flashing. The replacement batteries required are *Duracell 9 Volt Alkaline (2).6 Beeps 1-4 Wireless Smoke DetectorSupervisoryThe panel has not received a supervisory signal from the wireless smoke detector within the programmed time. Check WirelessSmoke Supervisory Timer [17] Programming. Check the placement of the wireless smoke detector and receiver, refer to WI850.7 Beeps 1-6 Zone Trouble The panel has one or more of the following 2 possible troubles: Transmitter Tamper or Dual Tech Self Test Fail.