26All On / OffThe All On/Off menu is used to turn all lighting unit numbers on and off.Note: UPB, CentraLite, and RadioRA devices are not affected by the OmniLT “All On” or “All Off” command. To achieve thisfunctionality, we suggest the following:UPB: Program a Link into each device that will respond to an OmniLT “All On” and “All Off” command program. For example:In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) thatwill go to 100% when activated (turned on). Then write the following programs in the OmniLT controller:WHEN ALL ON: LINK 50 ONWHEN ALL OFF: LINK 50 OFFCentraLite: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on theCentraLite.RadioRA: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).For example:WHEN ALL ON: PHANTOM BUTTON 16 ONWHEN ALL OFF: PHANTOM BUTTON 17 ONThis All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes.From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.ALL0=OFF 1=ON 2=SCN 3=LINK↓ALL4=PHANTOM 5=CENLIT ↓All Lights OnAt the ALL prompt, press the 1 (LIGHTS ON) key. The console will beep, and a command will be sent that turns on all specifiedX-10 or ALC units or HLC Rooms. X-10 Appliance Modules do not respond when the All Lights On command is sent. Byfactory default, all lighting units respond to the All-On command.NOTE: The All On function can be changed, if desired - See Set Up Misc, All On And All Off.All OffAt the ALL prompt, press the 0 (OFF) key. The console will beep, and a command will be sent that turns off all specified X-10and ALC units and HLC Rooms. By factory default, all lighting units respond to the All-Off command.NOTE: The All Off function can be changed, if desired - See Set Up Misc, All On And All Off.