66Dial OrderThe dial order is the order in which call all will be placed if an Alarm is activated.You can have the system make up to 8 calls in the event of an alarm. You may chose from Dial Out Numbers 1 - 8. You canhave the system dial a number twice (or more) which is suggested if you don't have a direct dial number at work, so that yourcompany operator can find you, if you aren't at your desk, and have you alerted for the next call.Up to eight numbers may be entered. Enter the Dial Out Order by pressing the keypad digits 1, 2, 3, 4, 5, 6, 7, or 8 for Dial OutNumbers 1, 2, 3, 4, 5, 6, 7, or 8, respectively. When you have entered the dial order of your choice, press ' # '. Enter a single ' 0 'if no dial out is desired. The default Dial Order is 1 2 3 4 5 6 7 8.Set Up ArmingTo configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key.Entry DelayThe Entry Delay is the time, in seconds, that you have to disarm the alarm system after entering your home. The Entry Delayonly applies to the entry/exit zone (e.g. your entry doors). If you (or someone else) come in through a window, there will be noentry delay and the alarm will sound immediately.When you come in through a door on an entry/exit zone, the other zones are delayed too. This allows you to get to your phone orconsole to turn off the security system, even if you have to go through a room protected by a motion detector.Some doors (a back door or garage door) may be configured as a Double or Quadruple Entry Delay. If so, that door has twotimes or four times the entry delay shown on the display.ENTRY DELAY: 3030-60 SECONDS ↓The default Entry Delay is 30 seconds. You may change it from 30 to 60 seconds.Exit DelayThe Exit Delay is the time, in seconds, that you have to leave your house when you turn on the system. When arming the systemin Day, Night, Away, or Vacation modes, the system will wait this amount of time before arming.EXIT DELAY: 6045-180 SECONDS ¦The default Exit Delay is 60 seconds. You may change it from 45 to 180 seconds.Exit Time RestartWhen Exit Time Restart is set to Yes, the Exit Delay will restart if the same exit zone is violated twice within the original exitdelay. For example, after arming the system if you open the front door to leave, close the front door behind you, and then reenterthrough the front door while the exit delay is still in effect, the exit delay will be restarted. This is designed to give you additionaltime to exit without causing an alarm. The exit time will only be restarted once within a given arming period.To configure Exit Time Restart, from the Set Up menu, press the 5 (ARM) key.EXIT TIME RESTART: 10=NO 1=YES ¦The default setting for Exit Time Restart is “Yes”.