Features and specificationsThe following table provides a summary of the features and specifications for thexSeries 330, IntelliStation R Pro, and Network Equipment Building System servers.Table 1. Features and SpecificationsMicroprocessor:v Intel® Pentium® IIImicroprocessor with MMX™technology and SIMD extensionsv 512 KB Level-2 cachev Supports up to twomicroprocessorsMemory:v Standard: 256 MBv Maximum: 4 GBv Type: 133 MHz, ECC, SDRAM,Registered DIMMsv Slots: 4 dual inlineDrives standard:v Diskette: 1.44 MBv CD-ROM: 24X IDEExpansion bays:v Two 3.5-inch slim high bays forLVD SCSI or IDE (depending onmodel) hard disk drivesPCI expansion slots:v Two 33 MHz/64-bitPower supply:One 200 watt (115-230 Vac)Video:v S3 Savage4 PRO Graphics/VideoAccelerator (integrated on systemboard)v Compatible with SVGAv 8 MB SDRAM video memoryHeat output:Approximate heat output in BritishThermal Units (BTU) per hourv Minimum configuration: 273 BTU(80 watts)v Maximum configuration: 751 BTU(220 watts)Size:v Height 43.69 mm (1.72″)v Depth: 653.29 mm (25.72″)v Width: 439.93 mm (17.32″)v Weight: approximately 12.7 kg(28lb) when fully configuredIntegrated functions:v Advanced System Managementprocessorv One Ultra160 SCSI controllerv Two 10BASE-T/100BASE-TX IntelEthernet controllersv Two Universal Serial Bus (USB)portsv Two RS-485 Advanced SystemManagement processor ports (oneIn, one Out)v One serial portv Two Cable Chaining Technologyports (IN, OUT)Acoustical noise emissions:v Sound power, idling: 6.1 belmaximumv Sound power, operating: 6.2 belmaximumElectrical input:v Sine-wave input (50-60 Hz)requiredv Input voltage low range:– Minimum: 100 V ac– Maximum: 127 V acv Input voltage high range:– Minimum: 200 V ac– Maximum: 240 V acv Input kilovolt-amperes (kVA)approximately:– Minimum: 0.08 kVA– Maximum: 0.22 kVAEnvironment (xSeries 330 andIntelliStation R Pro models):v Air temperature:– Server on: 10° to 35° C (50.0° to95.0° F). Altitude: 0 to 914 m(2998.7 ft.)– Server on: 10° to 32° C (50.0° to89.6° F). Altitude: 914 m (2998.7ft.) to 2133 m (6998.0 ft.)– Server off: 10° to 43° C (50.0° to109.4° F). Maximum altitude: 2133m (6998.0 ft.)v Shipping altitude: 0 to 10,668m(35,000ft)v Storage temperature: 1° C to 60° C(34° to 140° F)v Shipping temperature: -40C to 60C(-40F to 140F)v Humidity:– Server on: 8% to 80%non-condensing– Server off: 8% to 80%non-condensingv Storage humidity: 5 to 80%v Shipping humidity: 5 to 100%v Operating vibration: 0.27G RMS at5Hz to 500Hz for 30 minutesv Storage vibration: 0.5G at 2Hz to200Hz for 15 minutes (all faces);1.04GRMS Random for 15 minutes(all faces)v Operating shock: 3.5G for 3msv Storage shock: 50Gwith a velocitychange of 3860mm/sec (all faces)Environment (NEBS - NetworkEquipment Building System models):v System on:– Temperature: 5.0° to 40° C (41.0°to 104.0║ F). Altitude: -60 to 1800m (-197 to 5,905.0 ft.)– Relative humidity: 5% to 85%– Maximum altitude: 4,000 m(13,123.0 ft.)v System off:– Temperature: 5.0 to 40° C (41.0° to104.0° F). Altitude: -60 to 1800 m(-197 to 5,905.0 ft.)– Relative humidity: 5% to 85%– Maximum altitude: 4,000 m(13,123.0 ft.)4 Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment BuildingSystem Type 8674