7. Reinstall the server/workstation cover and connect the cables.8. Turn on the server/workstation.9. Start the Configuration/Setup Utility program and set configurationparameters.v Set the system date and time.v Set the power-on password.v Reconfigure the server/workstation.Temperature checkoutProper cooling of the system is important for proper operation and systemreliability. For a typical xSeries server/workstation, you should make sure:v Each of the drive bays has either a drive or a filler panel installedv The top cover is in place during normal operationv There is at least 50 mm (2 inches) of ventilated space at the sides of theserver/workstation and 100 mm (4 inches) at the rear of the server/workstationv The top cover is removed for no longer than 30 minutes while theserver/workstation is operatingv A removed hot-swap drive is replaced within two minutes of removalv Cables for optional adapters are routed according to the instructions providedwith the adapters (ensure that cables are not restricting air flow)v The fans are operating correctly and the air flow is goodv A failed fan is replaced within 48 hoursIn addition, ensure that the environmental specifications for the system are met.See “Features and specifications” on page 4.Note: The server/workstation is not designed to operate in an enclosedenvironment. The xSeries 330 should not reside behind a glass door in itsrack enclosure.For more information on specific temperature error messages, see “Temperatureerror messages” on page 131.Diagnostics 25