Chapter 3. Hardware configuration 159Figure 3-50 ServeRAID-MR10k initialization in POSTThe following message is prompting you to start the MR10k WebBIOS:Press for WebBIOS or press for Preboot CLIAfter you press Ctrl+H keys the WebBIOS starts after the POST finishes:WebBIOS will be executed after POST completesYou can migrate RAID-0 and RAID-1 volumes that you created using the onboardLSI1078 SAS controller to MegaRAID (MR) mode by installing theServeRAID-MR10k. The created volumes are automatically imported after thefirst installation of this controller.3.4.3 Working with LSI MegaRAID controller WebBIOSThe WebBIOS starts up with the initial window, which indicates all availableLSI SAS controllers that are installed in either the x3850 M2, x3950 M2, orx3950 M2 multinode complex, and initialized in the POST correctly.Figure 3-51 shows both installed ServeRAID MR10k controllers, within atwo-node x3950 M2 system.Figure 3-51 Adapter Selection menu: initialized controllers in POSTLSI MegaRAID SAS-MFI BIOS Version NT16 (Build Nov 20, 2007)Copyright(c) 2007 LSI CorporationHA -0 (Bus 4 Dev 0) IBM ServeRAID-MR10k SAS/SATA ControllerFW package: 8.0.1-0029Note: You cannot reverse this step to go back to using the onboard SAScontroller if you remove the ServeRAID-MR10k again.