Table 3-1 (Page 3 of 24). Firmware Error Codes.Error Code Description Action / Possible Failing FRU20E0000A EEPROM lock problem. If for privileged-access passwordinstall, is jumper in correct position?Consult the system's User's Guide forjumper location and position.1. Turn off, turn on system unit.2. Replace I/O board. (See notes on3-1.)20E0000B EEPROM write problem 1. Turn off, turn on system unit.2. Replace I/O board. (See notes on3-1.)20E0000C EEPROM read problem. 1. Turn off, turn on system unit.2. Replace I/O board. (See notes on3-1.)20E00017 Cold boot needed for password entry. Turn off, turn on system unit.20EE0xxx Informational20EE0003 IP parameter requires 3 dots "." Enter valid IP parameter.Example: 000.000.000.00020EE0004 Invalid IP parameter. Enter valid (numeric) IP parameter.Example: 000.000.000.00020EE0005 Invalid IP parameter (>255) Enter valid (numeric) IP parameter inthe range of 0 to 255.Example: 255.192.002.00020EE0006 No SCSI controllers present The I/O board should always have (atleast) 2 integrated PCI SCSIcontrollers; replace the I/O board. (Seenotes on 3-1.)20EE0007 Keyboard not found 1. Plug in keyboard.2. Replace I/O board, (See notes on3-1.)20EE0008 No configurable adapters found in thesystem.This warning occurs when the selectedSMS function cannot locate anydevices/adapters supported by thefunction. If a supported device isinstalled:1. Replace the device or adapter.2. Replace I/O board, (See notes on3-1.)20EE0009 Unable to communicate with theService processor.1. Replace the Service Processor.2. Replace I/O board, (See notes on3-1.)3. Replace System Board.3-4 Service Guide