Section: 7IDS X64 User Manual 700-398-01D Issued August 201018¾ All bypassed zones will be automatically cancelled each time the panel is disarmed and must bere-bypassed before the next arming.¾ To permanently bypass ones, create a stay profile and the zone. Refer to section 13 Stay Zones.7.1 Bypassing/Un-bypassing a ZoneHold down the [9] key until the beep,then enter [USER CODE] [*] [ZONE NUMBER] [*] [#]1. Ensure that the panel is not armed (ARM LED OFF).2. To enter bypass mode, hold down the [9] key for one second (until the keypad buzzer sounds).The AWAY LED will flash.3. Enter [USER CODE] followed by the [*] key. The bypassed zones will be indicated by zoneLEDs that are on.4. The READY LED will come on.5. Entering a zone number [ZONE NUMBER] followed by the [*] key will toggle the correspondingLED. For example, [2] [*] will turn LED 2 on (if it was off) and off (if it was on). The READY LEDwill come on.6. Turn on the LEDs corresponding to the zones you need to bypass. The zone LEDs should nowindicate only the zones that require bypassing.7. Press the [*] key to page through to see zones 17-32. If you press the [*] key again, you willview zones 33-48. And press the [*] key again to see zones 49-64.8. After each star press you can repeat steps 4-5.9. Once satisfied with your selection, press the [#] key to exit the bypass mode.NOTE:¾ Panic zones cannot be bypassed – and remember that all bypassed zones are reset at everypanel disarm cycle.¾ The READY LED will be on for page 1, zones 1-16.¾ The ARM LED will be on for page 2, zones 7-32.¾ The AWAY LED will be on for page 3, zones 33-48.¾ The POWER LED will be on for page 4, zones 49-64.8. Emergency Alarms8.1 Fire AlarmsHold down the [F] key until the beep¾ If the [F] key is pressed until the keypad beeps (approximately 1 second) a FIRE ALARMcondition will be activated.¾ The POWER LED stays on and the ARM LED flashes.¾ The FIRE ALARM condition may also be triggered by a smoke detector connected to anappropriately programmed zone.¾ The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE willbe transmitted to the monitoring company.¾ To silence the siren enter a valid [USER CODE].