Section: 13IDS X64 User Manual 700-398-01D Issued August 2010325. Program STAY and BUZZ zones for the profile (see section 13.2), and/or ARM the profile (with the[5] key).Menu Select Method:Hold down the [MODE] key until the beep,then enter [2] [*] [PROFILE NUMBER] [*]1. Ensure that the Panel is disarmed.2. Press the [#] key to clear any previous entries.3. Hold [MODE] down for one second until the keypad beeps.4. Press the [2] key followed by the [*] key.5. Press [1], [2], [3] or [4] for the required profile.6. Press the [*] key to enter. The buzzer will give a long beep.7. Program STAY and BUZZ zones for the profile, or ARM the profile13.2 How to Program Stay ZonesHold down the [3] key until the beep,then enter [ZONE NUMBER] [*] [#]1. Select the required stay profile (See section 13.1).2. Hold down the [3] key until the keypad buzzer sounds. The POWER LED will turn off, indicatingthat the panel is in the Stay zone programming mode.3. Entering a [ZONE NUMBER] will toggle the corresponding LED. For example, [2] [*] will turnLED 2 on (if it was off) and off (if it was on). (Flashing zone LEDs indicate zones that have beenset as Buzz zones and therefore cannot be changed in this menu – refer to section 14.1 on howto program buzz zones.).4. Turn on the LEDs corresponding to the zones you need to be Stay zones. The zone LEDs shouldnow indicate only the zones that you require to be Stay zones5. Press the [*] key to page through to see zones 17-32. If you press the [*] key again, you willview zones 33-48. And press the [*] key again to see zones 49-64.6. After each press of the [*] key, you can repeat steps 3-5.7. Once satisfied with your selection, press the [#] key to exit the Stay zone mode.NOTE:¾ Panic zones cannot be selected as Stay zones.¾ Buzz zones (shown by flashing LEDs), cannot be selected as Stay zones. The Buzz status mustbe cleared first.¾ The READY LED will be on for page 1, zones 1-16.The ARM LED will be on for page 2, zones 7-32.The AWAY LED will be on for page 3, zones 33-48.The POWER LED will be on for page 4, zones 49-64.14. Buzz ZonesViolation of a Buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30seconds during which time a valid user code must be entered. If a valid user code is not entered duringthis period, the system will register an alarm condition. This feature helps prevent unnecessary falsealarms.