Section: 12IDS X64 User Manual 700-398-01D Issued August 201028Table 9: An Example on how to Read User Outputs on an LED KeypadOUTPUT ACTION OUTPUT NUMBERZone LEED Calculation Zone LED Calculation1 (x 1 = 1) 9 (x 1 = 0)2 (x 2 = 0) 10 (x 2 = 2)11 (x 4 = 4)12 (x 8 = 0)13 (x 16 = 0)14 (x 32= 0)15 (x 64 = 0)16 (x 128=0)NOTE:¾ If output action 0 is chosen, then LEDs 1 and 2 will be off.¾ If output action 1 is chosen, then LED 1 will be on.¾ If output action 2 is chosen, then LED 2 will be on.¾ If output action 3 is chosen, then LEDs 1 and 2 will be on.¾ The Programmable Output Code in User Code Properties – Option 10, must be enabled in orderfor the user outputs to work.Table 10: Output Address Physical Mapping DataAddress Physical Outputs Address Physical Outputs00 Disabled 21 Reserved01 Onboard output 1 22 Reserved02 Onboard output 2 23 Reserved03 Onboard output 3 24 Reserved04 Onboard output 4 25 Reserved05 Onboard output 5 26 Reserved06 Zone expander 1 output 1 27 Reserved07 Zone expander 1 output 2 28 Reserved08 Zone expander 2 output 1 29 Reserved09 Zone expander 2 output 2 30 Reserved10 Zone expander 3 output 1 31 Reserved11 Zone expander 3 output 2 32 Reserved12 Zone expander 4 output 1 33 Reserved13 Zone expander 4 output 2 34 Keypad 1 output14 Zone expander 5 output 1 35 Keypad 2 output15 Zone expander 5 output 2 36 Keypad 3 output16 Zone expander 6 output 1 37 Keypad 4 output17 Zone expander 6 output 2 38 Keypad 5 output18 Reserved 39 Keypad 6 output19 Reserved 40 Keypad 7 output20 Reserved 41 Keypad 8 output