38The Elevator drive uses a special operator which provides a user inter-face and functionality specific to elevator applications. The operator mustbe plugged into the drive in order for the drive to function correctly.Unplugging the operator while the drive is in operation will result inimmediate shutdown of the drive and will cause the ready relay todrop and the fault output to activate. If it is necessary to remove theoperator, do so while the elevator is standing still!4. Operation of the unitANTRIEBSTECHNIKSTARTSTOPFUNC.SPEEDENTERF/RANTRIEBSTECHNIKDouble function keypadOperating-Error displayNormal "LED on"Error "LED blinks"5-digit LED Display4.1 Digital OperatorPIN RS485 Signal Meaning1 – – reserved2 – TxD Transmitter signal, RS2323 – RxD Receiver signal, RS2324 A' RxD-A Receiver signal A, RS4855 B' RxD-B Receiver signal B, RS4856 – VP Voltage supply-Plus +5V (I max = 10 mA)7 C, C' DGND Data reference potential8 A TxD-A Transmitter signal A, RS4859 B TxD-B Transmitter signal B, RS485Interface controlTransmit "LED on"Only use the operator interface for the serial data transfer to RS232, 485.The direct connection from PC directly to the Elevator Drive, i.e .not to theoperator, is only possible with a special cable, otherwise it will lead to thedestruction of the PC-interface. Consult the factory for more information.RS232, RS485Elevator Operator: Part No. 00.F5.060-20105 4 3 2 19 8 7 6