AX MIG WelderOperating manual - ENParameter DescriptionGeneralCommunicationOKGreen light: The status data transfer between the welding system and the robot works.No light: The status data transfer between the welding system and the robot does not work.Power sourceError No light: No errors are active.Red light: There is an error in the welding system that prevents welding.Select the error symbol for more information.System Green light: The welding system is ready for welding. All system devices are correct and working.No light: The welding system is not ready for welding.Power source Green light: The power source is ready to start a new weld.No light: The power source is not ready to start a new weld.Arc on Green light: The welding arc is established.No light: The welding arc is not established.Cycle on Green light: The welding cycle is in progress (the pre gas and post gas phases are included in the weldingcycle).No light: The welding cycle is complete.Collision Red light: A collision is detected.No light: No collision is detected.Sensed with wire /gas nozzleGreen light: A contact between the touch sensor (gas nozzle or wire) and the work piece has been detected.No light: No touch is sensed.Water flow Green: Coolant is circulating.No light: Coolant is not circulating.© Kemppi 120 1921900 / 2318