AX MIG WelderOperating manual - EN43 Overcurrent inwire feedermotorThere may be too much pressure in thewire feed rolls or dirt in the wire line.Adjust the feed roll pressure. Clean the wire line. Changeworn parts in the welding gun.44 Wire speedmeasurement ismissingFaulty sensor or wiring in wire feeder. Restart the welding system. If problem persists, contactKemppi service.50 Welding pro-gram errorRequired welding program is notinstalled.Contact Kemppi service for installing welding programs.51 Rear drive rollslippingWire feeder’s rear drive roll is slipping. Adjust the feed roll pressure. Clean the wire lines.53 Collision detec-tedWelding torch has collided with anobject.Move the welding torch away from the collision andcheck the torch for any damage.56 Wire feeder hard-ware faultThere is an internal hardware fault inwire feeder.Check wire feeder connections and restart the weldingsystem. If problem persists, contact Kemppi service.57 Low shieldinggas flowShielding gas flow is below the warninglevel or missing.Check and adjust the shielding gas flow.61 Operation notallowedSubfeeder is connected, but it has notbeen selected in the system settings.Go to the system settings menu on the control panel andselect your subfeeder model and type.62 Power sourcenot foundNo power source is connected to thewire feeder, or connection is faulty.Check the control cable and its connectors.64 Robot controldevice lostWire feeder lost connection to the robotcontrol device.Check the robot control device and interconnectioncables. If problem persists, contact Kemppi service.65 Subfeeder notallowedUse of subfeeder is not allowed withselected welding process.Remove the subfeeder or change the welding process.81 Welding pro-gram data miss-ingWelding program data has been lost. Restart the power source. If problem persists, contactKemppi service.103 Empty memorychannelRobot tried to start welding using anonexistent memory channel.Check the memory channel selected by the robot.130 RCM hardwarefaultThere is an internal hardware failurewithin the RCM.Check any external I/O connections, optional add-oncards and add-on card power supplies, if applicable. Ifproblem persists, contact Kemppi service.131 Fieldbus ini-tialization failedRCM failed to initialize the fieldbus mod-ule. Either the module is unsupported orit is faulty.Remove the fieldbus module and check if it is supportedby the RCM.132 Robot notrespondingThere is a communication problembetween robot and the RCM.Check fieldbus cabling, connectors and the fieldbus mod-ule.133 Stop switchpressedWelding system has been stoppedbecause the stop switch is pressed.Release the stop switch.134 Gate door open Gate door has been opened. Close the gate door.238 Power sourceserial number ismissingCommunication to serial number cardfailed.Restart welding system. If problem persists, contactKemppi service.244 Internal memoryfailureInitialization failed (%sub:%device). Restart welding system. If problem persists, contactKemppi service.250 Internal memoryfailureMemory communication failed. Restart welding system. If problem persists, contactKemppi service.© Kemppi 152 1921900 / 2318