Release 6.0 169User Guide Chapter 6 Initializing a Disk Array (iSCSI)6.1 OverviewTo set FC connection first in a disk array configured for both FC and iSCSI connections, see Chapter 5,"Initializing a Disk Array (FC)" to make the setting and then perform the procedure in this chapter.To set iSCSI connection first, perform the procedure in this chapter and then see Chapter 5, "Initializinga Disk Array (FC)" to make setting.The initialization consists of:1. Initializing the disk array by using the initialization wizardUse the initialization wizard to make the basic settings of disk array.For details about the procedure, see Section 6.2.1: “Initialization Wizard”.2. Setting by using iSCSI Setup ToolUse the iSCSI Setup Tool to make the setting required for the application server.For details about the procedure, see Section 6.2.2: “iSCSI Setup Tool”.3. Binding poolBind a pool in the disk array.For details about the procedure, see Section 6.2.3: “Binding a Pool”.4. Binding hot spareBind hot spare. This step is not required unless a hot spare is bound.For details about the procedure, see Section 6.2.4: “Binding a Hot Spare”.5. Binding logical diskBind logical disks.For details about the procedure, see Section 6.2.5: “Binding Logical Disk”.6. Assigning the logical disks to application serversAssign the logical disk to the application servers.For details about the procedure, Section 6.2.6: “Assigning Logical Disk”.7. Checking connection from the application serversCheck that the application servers to which the logical disk has been assigned can access the diskarray.For details about the procedure, see Section 6.3: “Checking Connection from Application Server”.To initialize a disk array configured for FC connection, see Chapter 5, "Initializing a DiskArray (FC)" .