Release 6.0 353User Guide Appendix C How to Set/Check Application Server (Windows) (iSCSI)C.3.3 Check the PathManager Settings and StatusWhen PathManager is not used, it is not necessary to perform this step.After checking the FC cable connection between the application server and disk array unit, restart theserver and run the following command from the command prompt.Check PathManager statusRun the following command from the command prompt.spsadmin /lunCheck the message shown after the command is executed, and then check the number of logical disksassigned to the server, the number of access paths per logical disk, and each path status.Display example: When two logical disks are assigned to a server, with two access paths per logicaldisk. For details, refer to the PathManager User's Guide (Windows Version).C:\>spsadmin /lun+++ LogicalUnit #0 +++SerialNumber="0000000995000001", LDNumber=0x00000LoadBalance=Least Size0: ScsiAddress=2:0:0:0, Priority=1, Status=Active1: ScsiAddress=3:0:0:0, Priority=2, Status=Standby+++ LogicalUnit #1 +++SerialNumber="0000000995000001", LDNumber=0x00001LoadBalance=Least Size0: ScsiAddress=2:0:0:1, Priority=1, Status=Active1: ScsiAddress=3:0:0:1, Priority=2, Status=StandbyIf nothing is displayed, none of the access paths recognized the logical disks of the diskarray unit assigned to the application server. Check the connection between theapplication server and the disk array unit, the Access Control settings, host bus adapterdriver settings, and other settings.