Issue 1.0 UNIVERGE SV81002 - 266 Program 21 : Outgoing Call SetupDescriptionUse Program 21-05 : Toll Restriction Class to set the system Toll Restriction classes(1~15).Program 21 : Outgoing Call Setup21-05 : Toll Restriction ClassLevel:INInput DataToll Restriction Class Number 1~15ItemNo. Item Input Data Default Description RelatedProgram01 International CallRestriction Table 0 = Unassigned(No)1 = Assigned(Yes)1, 6~15 = 02~5 = 1This option assigns/unassigns theInternational Call Restrict Tablefor the Toll Restriction Class youare programming. EnterInternational Call Restrict Tabledata in Program 21-06-01.21-06-0102 International CallPermit Code Table 0 = Unassigned(No)1 = Assigned(Yes)1, 3~15 = 02 = 1This option assigns/unassigns theInternational Call Permit Table forthe Toll Restriction Class you areprogramming. Enter InternationalCall Permit Table data in Program21-06-02.21-06-0203 --- Not Used ---04 Maximum Number ofDigits TableAssignment1~4 = Table0 = Disable(None)1, 2, 6~15 = 03 = 14 = 25 = 3Select the table (defined in21-06-03) to be used to determinethe maximum number of digitsallowed for outgoing calls.21-06-0305 Common PermitCode Table 0 = Unassigned(No)1 = Assigned(Yes)1, 8~15 = 02~7 = 1It chooses whether the table setup by 21-06-04 is referred to, ornot referred to.21-06-0406 Common RestrictionTable 0 = Unassigned(No)1 = Assigned(Yes)1, 6~15 = 02~5 = 1It chooses whether the table setup by 21-06-05 is referred to, ornot referred to.21-06-0507 Permit Code Table 1~4 = Table0 = Disable(None)1, 2, 6~15 = 03 = 14 = 25 = 3Set the tables 1~4 when referringto the table set up by 21-06-06.21-06-06