UNIVERGE SV8100 Issue 1.0Programming Manual 2 - 705DescriptionUse Program 90-10 : System Alarm Setup to assign a status to system alarms. Youcan designate an alarm as Major or Minor. This program also assigns whether or notthe alarm is displayed to a multiline terminal and whether or not the alarm informationis reported to the pre-defined destination.Program 90 : Maintenance Program90-10 : System Alarm SetupLevel:INInput DataAlarm Number 001~100ItemNo. Item Input Data01 Alarm Type 0 = Not Set1 = Major Alarm2 = Minor Alarm02 Report 0 = Not Report (No autodial)1 = Report (autodial)Table 2-20 Description of AlarmAlarmNo. Type Report Name Content of Alarm Cause Action Recovery AlarmStatus1 2 0 PKG InitializeError.1. The PKG failed toinitialize.2. The PKG did not startnormally.1. PKG not insertedfirmly.2. PKG wasremoved, but notreinserted firmly.3. Old PKG datastill reported due tono initialization.1. Insert PKG firmly.2. Insert PKG firmly.3. Delete slotinformation inPRG 90-05 and reinsertthe PKG.Uponinitialization,the PKG isrecognized.ERRREC2 2 0 PKG Mount-ing ErrorThe unit did not step on aregular procedure and itwas pulled out. Or, it is notnormally inserted.1.The package ishalf.2.The package isout of order.1.Please insert thepackage firmly.2.Please try again afterinitializing the systemdata once when LEDdoesn't blink normally.3.Exchange ofpackages.When the unitisreconfirmed,the error isrecovered.ERRREC