UNIVERGE SV8100 Issue 1.0Programming Manual 2 - 581DescriptionUse Program 51-16: NetLink System Data Replication Mode Setting to set thesystem data replication between the Primary and Secondary systems.Program 51 : NetLink Service51-16 : NetLink System Data Replication Mode SettingLevel:INInput DataItemNo. Item Input Data Default01 System Data Replication ModeSets the synchronous mode of the system data.When set to 1 (Setting Time Mode), the systemsare synchronized at the time set in Item 02below.When set to 2 (Interval Mode), the systems aresynchronized at regular time intervals set in Item03 below.0 = Disable1 = Setting Time Mode2 = Interval Mode002 System Data Replication Time SettingSets the time of day that both systemssynchronize database (when Item 01 is set to 1.)0000~2359 020003 System Data Replication Interval SettingSets the time interval that both systemssynchronize database (when Item 01 is set to 2).15~1440 (minutes) 30 (min)04 Replication Time StampShow next replication time. (Read-Only)Month: 0~12 –Day: 0~31 –Hour: 00~23 –Minute: 00~59 –05 System Data Replication Wait TimeThis sets the wait time until replication startswhen NetLink is created.1~86400 (seconds) 180 sec06 System Data Replication IntervalThis program sets an interval time to startreplication to the next node after replication toone node is completed.0~86400 (seconds) 1 sec