UNIVERGE SV8100 Issue 1.0Programming Manual 2 - 613DescriptionUse Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define thevarious basic timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).Program 81 : Basic Hardware Setup for Trunk81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer SetupLevel:INInput DataLayer 3 Timer Type Number 1~5ItemNo. Item Description Input Data Default01 T301 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen the ALERT message isreceived.0,180~254 (sec) 180 (sec)02 T302 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen the SETUP ACK is sent. Timeris also restarted when INFO isreceived.1~254 (sec) 15 (sec)03 T303 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen SETUP is sent.1~254 (sec) 4 (sec)04 T304 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen the SETUP ACK is received.Timer is also restarted when INFO isreceived.0~254 (sec). 30 (sec)05 T305 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen DISC without progress No. 8 issent.1~254 (sec) 30 (sec)06 T306 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen DISC with progress indicatorNo. 8 is sent. This timer is valid forNetwork side use only.0~254 (sec) 30 (sec)07 T307 Specifies the timer value in 1/100thsof a second of the timer to be startedwhen SUSPEND ACK is sent. Thistimer is valid for Network side useonly.1~254 (sec) 180 (sec)