35Service Manual – SC6000 04 - Control SystemFwd Speed Max (%): This sets the maximum speed (percent of maximum) the operator can propel themachine forward The minimum is 50%, the maximum is 100%, and the increment is every 10%Lock Speed Limit: This sets whether the operator can use the “set max speed” feature.Inactivity Time (min): This sets the length of time (in minutes) before the machine powers down afterinactivity The minimum is 1 minute, the maximum is 30 minutes, and the increment is every minuteImpact Detect: This sets how the machine handles impact detection The choices are Off, record to log, andlockout the machineImpact Level: This sets the threshold for impact detection The choices are high and lowConfiguration MenuThe configuration menu provides technician-only access to configure the machine based on which optionsare installed. If you install an option to a customer’s machine, you will need to configure the controller tospecify that the option is installed, or the option may not function Additional information is contained in theinstruction sheets that accompany the option kitsBrand: This sets the branding of the machine (Nilfisk or Advance). This should never be changed unless youare replacing the main controllerDeck: This sets the deck type installed on the machine. The options are (Advance/Nilfisk) 34D/860D,40D/1050D, and 36C/910CSide Broom: This sets whether the optional side broom is installed This option is available only for36C/910C machines If the side broom kit also includes Dust Guard, you will also need to set the optionpump type tooEcoflex: This sets whether the EcoFlex detergent pump system is installedOpt Pump: This sets whether the option pump is installed, and which of the two choices are used Thechoices are None, Spray Wash, and Dust Guard Note that the same machine cannot have both the sprayhose and Dust Guard options installedBattery: This sets the battery type for the purpose of battery voltage monitoring The choices are Wet andAGM The battery types will have slightly different voltage levels during their discharge cyclesCharger: This sets whether the onboard battery charger is installed Note that if you set this to Yes, but nocharger is installed, the machine will be disabled Likewise, setting this to No when a charger is installed,can result in damage to the charger Refer to the Troubleshooting section, “Onboard Charger Interlock” onpage 67 for steps toVacuum: This sets whether there is 1 vacuum motor or 2 vacuum motorsBackup Alarm: This sets whether the backup alarm is installedHeadlight: This sets whether the headlights are installedTrackClean: This sets whether the TrackClean module is installed