Installation A 1-17E 2000 Nordson CorporationAll rights reserved 41-3000VIssued 5/00A3EN-04-[3V-A-AAXP]-12To make the electrical connections inside the unit, follow this procedureto open the unit and access the electrical enclosure.WARNING: Risk of equipment damage, personal injury, ordeath. Disconnect and lock out electrical power to the unit.1. Place the unit’s POWER switch in the off position and disconnect andlock out electrical power to the unit at the branch circuit disconnectswitch.2. See Figure A 1-11. Loosen the captive screws on the electricalenclosure lid, lift the lid from the unit, and prop it against the pumpcover. Take care not to disconnect the ground wire.3. Make sure the support strap is not wrapped around any boardcomponents. Untangle the strap if necessary.4. Loosen the two captive screws on either side of the control-end frameand lower the frame. You may need to pull the front and rear panelsapart to release the frame.5. Avoid direct contact with internal electrical connections, components,or wiring.6. Make sure all ground wires are securely connected.4130849AFig. A 1-11 Opening the Electrical EnclosureOpening the ElectricalEnclosure