InstallationA 1-30E 2000 Nordson CorporationAll rights reserved41-3000VIssued 5/00A3EN-04-[3V-A-AAXP]-125. See Figure A 3-19. Size your electrical service line based on themaximum amperage shown in the AMPS (max.) portion (2) of theidentification plate. The line must also meet local electrical coderequirements.WARNING: Risk of equipment damage, personal injury ordeath. Install a strain relief to protect wires from beingdamaged by the edges of the knockout hole.CAUTION: Circuit boards can be easily damaged. Avoid anycontact with circuit boards when removing a knockout hole plug.6. If you have not already done so, remove and discard the plug from aknockout hole on either the back side or the bottom of the unit(whichever is most convenient for your operation) and install a strainrelief in the hole. Refer to the following table for the appropriate sizestrain relief.NOTE: Your unit may have several knockout holes. You should routeyour electrical service wiring through a smaller hole.Size of Knockout Hole Size of Strain Relief to Install23 mm ( 15/16 in.) PG-16 or 1/2-in. trade size29.5 mm ( 15/ 32 in.) PG-2135 mm (13/8 in.) 1-in. trade sizeConnecting Electrical Service(contd.)