118 Chapter 8 Completing the processReturning CallPilot to serviceIf the upgrade was not successful, use the following procedure to restorethe CallPilot system.Restoring CallPilot after a failed upgrade (RAID)Step Action1 Reboot the CallPilot server.2 Press Ctrl+M while the server boots.Result: The RAID configuration utility appears.3 Break the mirroring of the logical drives.a. Select Objects > Physical Drive.Note: All server drives on channel 1 must be online: twodrives for the 703t and six drives for the 1002rp.b. Select CH1 ID0 (A01-01) and press Enter.c. Select Fail Drive and press Enter.d. Select Yes to confirm the fail action and press Enter.e. Repeat these steps for each remaining drive on channel 2: CH1ID1 (A02-01) and CH1 ID2 (A03-01).Note: The 703t and 1005r servers have only one drive onchannel 1. The 1002rp server has three drives on channel 1.4 Bring the drives on channel 2 online (the drives on which theprevious CallPilot release is installed).a. Select Objects > Physical Drive.b. Select CH2 ID0 (A01-02) and press Enter.c. Select Make Online and press Enter.d. Select Yes to confirm that the driver must be brought onlineand press Enter.e. Repeat these steps for each remaining drive on channel 2: CH2ID1 (A02-02) and CH2 ID2 (A03-02).Note: The 703t and 1005r servers have only one drive onchannel 2. The 1002rp server has three drives on channel 2.5 Press Esc to return to the Objects menu.6 Press Esc to return to the Management menu.7 Press Esc to exit the RAID configuration utility.Nortel CallPilotUpgrade and Platform Migration GuideNN44200-400 01.12 Standard5.0 24 April 2009Copyright © 2007–2009, Nortel Networks.