50 Chapter 3 Preparing the system for upgrade• Size: accept the size displayed• Accept• SPAN: NO13 Select Accept and press Enter to accept these new values. Repeatfor the two remaining logical drives.After you configure the last logical drive, the system prompts youto save the configuration.14 Select YES and press Enter.15 Press ESC twice to exit the submenus.16 On the Management menu, choose the Initialize submenu.17 Press F2 to select all three logical drives.18 Press F10 and consecutively select YES to initialize the drive packs.19 When the initialization is complete, press any key to return to theManagement menu.20 Press ESC to exit the utility.21 Save the configuration when prompted.22 Press Ctrl+Alt+Del as indicated by the menu to reboot.—End—What is next?Proceed to Chapter 4 "Updating the server" (page 61).Updating the RAID subsystemIf the CallPilot 5.0 Upgrade Wizard indicates that one or more of your RAIDcomponents requires updating, follow the applicable procedure.ATTENTIONEnsure that your RAID is not in a degraded state (the RAID is not split).Nortel strongly recommends that you perform a graceful stop of CallPilot servicesbefore you proceed to upgrade.• If you are running CallPilot 2.02 (2.01.27.05) or 2.5, proceed to"Updating your RAID subsystem: CallPilot 2.02 or 2.5" (page 51).Nortel CallPilotUpgrade and Platform Migration GuideNN44200-400 01.12 Standard5.0 24 April 2009Copyright © 2007–2009, Nortel Networks.