Replacing your hard drives 47What is next?If your server is a 201i or 1002rp, proceed to "Replacing your hard drives"(page 47). Otherwise, proceed to "Splitting the RAID drives" (page 56).Replacing your hard drivesThe following hard drives may not meet CallPilot 5.0 capacity requirements:Note: The upgrade wizard will detect if your hard drives need to beupgraded.• The 201i hard drive must be a minimum of 20 GB• The 1002rp hard drives must be a minimum of 36 GB.Replacing the 201i hard driveStep Action1 Shut down the Windows operating system.2 Remove the 201i server from the card cage.3 Remove the hard drive. Refer to CallPilot 201i Server Maintenanceand Diagnostics (NN44200-500) for instructions.4 Install the new drive.Refer to the written procedure included in the CallPilot 5.0 IPE 201idisk drive upgrade kit NTZE58AA for instructions.5 Insert the server back into the card cage.6 Proceed with Chapter 4 "Updating the server" (page 61).—End—Replacing the 1002rp hard drivesStep Action1 Label the hard drives according to their position in the server. Forexample, drives 1 to 6 from left to right. Keep these drives as abackup in case you need to back out of the upgrade.2 Power off the server and remove all hard drives.Nortel CallPilotUpgrade and Platform Migration GuideNN44200-400 01.12 Standard5.0 24 April 2009Copyright © 2007–2009, Nortel Networks.