2. Program Change How to Use the Basic Program24 NFS-640 Programming Manual P/N 51333:B 10/03/2003How to Modify an Addressable Control Module PointWhen you select a point address for modification, the control panel returns a screen that displaysinformation about the point. For example, the illustration below shows sample information for a controlmodule (2M101) in the LCD display.To modify a point, follow these steps:Note: A blinking cursor indicates the selected field.1. From the programming screen, use the arrow keys to move to a field that you want to modify. Seebelow for descriptions and settings.Table 7 Modifying Control Module Programming Selections2. When finished modifying a point, press the ENTER key; then press the NEXT or PREVIOUS key toselect another point.Field Description Set as follows:Type Code Specifies the function of the control module Press the NEXT or PREVIOUS Selection keys to scrollthrough valid control module Type Code selections (listedin Table 34 on page 106)Custom Label 20 character custom label. Change by placing the cursor into the first space of the fieldusing the arrow keys, then typing the descriptor.Note: Spaces must be input by the user, including any spacenecessary between the custom and extended label fields. An80-column printout will run the two fields together.Extended Label 12 character custom label extension. See “Custom Label” above.CBE list Up to five software zones can be entered todefine the output responses of the controlmodule based on various initiatingconditions (events)Type the number of up to five zones, including E0-E9, F0-F9, L0-L9, R0-R9, and zones 00-99. The first zone defaultis Z00 (general alarm).Switch Inhibit Specifies if an operator can manuallyactivate an outputType one of the following entries.I = Switch Inhibit enabled* = no switch inhibit (default for all but releasing circuits)Silenceable Specifies if an operator can manually silencean activated outputType one of the following entries.* = output nonsilenceableF = silenceable, resound by fire alarmU = silenceable, resound by supervisory alarmB = silenceable, resound by security alarmT = silenceable, resound by troubleO = silenceable, does not resoundNote: If the “Strobe” Type ID is used with System SensorStrobe synchronization, F, U, B, T, or O will silence theentire circuit, “*” will silence the horn portion only.Walk Test Specifies if outputs sound during Walk Test Type one of the following entries.W = devices sound (Basic Walk Test)* = devices do not sound (Silent Walk Test) (default)Walk Test Selection: *=off(default); W=selectedSilenceable: S=selected; *=off (default)Note: On a control module, the default zoneis always set to Zone 00 (general alarm).Default zoneBlinking Type Code selectionCBE list(five zones)12 spaces for extendedcustom label SLC number (1 or 2)M (module)SLC address (001-159)Switch Inhibit: I=selected; *=off (default)PROGRAM CONTROL MODULE CONTROL 2M10100 __ __ __ __ ISW 2M10120-character user-editable custom labelwww.PDF-Zoo.com