G3 Series EtherNet/IP Technical ManualPage 9TDG3EPTM1-1EN 05/09Subject to change without noticewww.numatics.com/g3Z-Board™ and Ribbon Cable ExampleIf fourteen (14) single solenoid and one (1) double solenoid valves are connected directly to thecommunication node via their Z-Boards™, and one (1) single solenoid and four (4) double solenoid valvesare connected to the communication node via the ribbon cable, the following would be the valve side bitmap:Output Word 0 1Output Byte 0 1 2 3Output Bit No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31Solenoid CoilOutput No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 n/aIn the above example, Output Bits No. 25 thru No. 31 are allocated butnot used. Allocation may be changed by configuration changes in thecommunication module (node). Refer to page 23 in this manual.NOTE!