G3 Series EtherNet/IP Technical ManualPage 26TDG3EPTM1-1EN 05/09Subject to change without noticewww.numatics.com/g3Advanced Settings - I/O Diag. MenuI/O Status Steps1. Press the SET button to enter the ADVANCED SETTINGS sub-menu.2. Press the SET button to enter the ADVANCED MENU / SET STATUS.3. Press the SET button to enter the SET STATUS / I/O STATUS.4. The current state of the parameter is shown.5. Press the SET button to change this parameterUse the NEXT button to scroll through the choices to enable/disable theDiagnostic status for I/O.a. ENABLED (Factory Default)b. DISABLEDc. RETURN (this will return you to the SET STATUS menu)Press the SET button to confirm your choice.6. Press NEXT to confirm the warning message.7. Press the NEXT button to select Yes or No to accept the selectiona. Selecting No will bring you back to the main SET STATUS menu.b. Selecting Yes will take you to the following saved settings menu.Press the SET button to confirm your choice.Save Settings Steps8. Press the NEXT button to select either NOW or LATER.a. Selecting NOW will cause the node to reset and apply the newsetting.b. Selecting LATER will cause the new I/O STATUS selection to besaved in memory, you must Accept the saved changes before yournext power cycle otherwise they will be lost.Press the SET button to confirm your choice.ADVANCEDSETTINGSADVANCED MENUSET STATUSSET STATUSI/O STATUSI/O STATUS.ENABLEDI/O STATUSDISABLEDI/O STATUSRETURNINPUT MAPPINGWILL SHIFTACCEPTDISABLED Y NSAVE SETTINGSNOW LATERI/O Status Bits are diagnostic bits. They include the valve coil status bits,AUX Power status bits, and Short Circuit & Alarm status bits of variousI/O modules.NOTE!I/O STATUSENABLED