Ranger RP22Counting3 CountingThe compact scales Ranger RP have additional functions for piece counting.The relevant settings in the menu are described in Section 4.4.1.3.1 Counting parts into a container1. Place the empty container on the scale and press TARE.The container is tared and the zero display appears.2. Place 10 reference parts on the scale and press Sample 10.-or-Place the number of pieces displayed above the key Sample Size on the scaleand press Sample SizeThe scale determines the average piece weight and then shows the number ofpieces.3. Add more parts to the container until the required number of pieces is reached.4. When the piece counting is completed, press the key C to clear the result.The scale is ready for the next weighing or counting.Note • The average piece weight remains saved in the factory setting until a new averagepiece weight is determined.• With Count Weight it is possible to switch between the number of pieces and theweighing units preset.• Depending on the assignment, it is possible to display the average piece weight,i. e. the weight of an individual reference unit, with Info.• If A.CL-APW ON is set in the menu, the average piece weight is automaticallycleared after each counting operation. The average piece weight must be deter-mined again for the next counting operation.• If ACCurCY ON is set in the menu, the accuracy achieved is briefly shown afterthe number of pieces is determined.