CodabarCommand Structure 1:3 ratio B0bbcccd (data) d2:5 ratio BD0bbcccd (data) d1:2 ratio D0bbcccd (data) dbb = Width of narrow element in dots (01~12)ccc = Bar height in dots (001~999)d = Required Start and Stop character (A,B,C, or D)(data) = Bar code data (alphanumeric)Character Set 0-9, -, $, :, /, +A, B, C, D (Start/Stop characters)Density TableNarrow/WideRatioValue of “bb” “X” Dimension(mils)Density(char/inch)1:3 01 5.0 16.91:3 02 10.0 8.52:5 01 10.0 9.21:2 02 5.0 10.2Example H400V25B002100A12345BH440V135XS12345Notes You must add the appropriate (A, B, C or D) Start and Stop characters to thedata string. The printer does not automatically add them when printing.109