Oki Data CONFIDENTIAL44158801TH Rev.2 196 /6.6.2 Updating by Running the Scanner in Loader ModeThis update method is used in the following circumstances.- The scanner does not start normally after its power is turned off during firmware update.- Update with an OKI network setup tool fails.- After the scanner power is turned on, the display does not changes to the standby screen.The flow of update is as follows: start the scanner in Loader mode first and then update onlyhe system firmware with an “upload” tool. After that, update every firmware with an OKI networksetup tool described in section 6.6.1 above.The followings are the steps to update.Directly connect a PC and the scanner with a network crossing cable.* It is unnecessary to connect them with a network crossing cable if they are alreadyconnected to the network in the LAN environment.Turn off the scanner power, hold down the numeric key “1” and turn on the scannerpower.The scanner is started in Loader mode.The scanner LCD displays the version of the loader and the IP address of the scanner.Enter the same subnet address of the IP address for the PC and the scanner.IP address of the scanner: 192.168.1.1IP address of the PC: 192.168.1.2Make sure that “upload.exe” and “upld.dll” files are in the same folder.Run “upload.exe”.Enter the IP address of the scanner and click the “OK” button.(Example: when the IP address is 192.168.1.1)