29400 STILL TIMER 0000000100020003000400050006000700080.5S5S10S20S30S40S50S1min2minFor setting the time taken before the unit is set to the tape protection modewhen it has been left in the STOP or STILL mode.(Unit: S = seconds, min: minutes)401 SRC PROTECT00000001STEPHALFFor setting the tape protection mode operation when the unit has been leftin the STILL mode.0: STEP FWD1: STANDBY OFF (half loading)When STEP FWD has been set, the unit is automatically transferred to theSTANDBY OFF (half loading) mode when it has been left in the STILLmode for a total of 30 minutes.403 STOP PROTECT00000001STEPHALFFor setting the tape protection mode operation when the unit has been leftin the STOP mode.0: STEP FWD1: STANDBY OFF (half loading)When STEP FWD has been set, the unit is automatically transferred to theSTANDBY OFF (half loading) mode when it has been left in the STOPmode for a total of 30 minutes.402 DRUM STDBY00000001OFFONFor setting the drum operation in the STANDBY OFF (half loading) mode.0: The drum stops rotating.1: The drum continues to rotate.TAPE PROTECTItem SettingNo. Superimposeddisplay No. SuperimposeddisplayDescription of settingThe underlining denotes the factory mode.Setup Menus202 ID SEL000000010002OTHERDVCPROORIGFor setting the ID information to be returned to the controller.0: 20 25H is returned.1: The ID (F0 33H) unique to the DVCPRO is returned.2: The ID (A0 51H) unique to the unit is returned.INTERFACEItem SettingNo. Superimposeddisplay No. SuperimposeddisplayDescription of settingThe underlining denotes the factory mode.