22O When the beginning or end of the tape has beendetected in the VTR operation mode, “BOT(beginning of tape)” or “EOT (end of tape)” isdisplayed at the beginning of the line.Examples of what is displayed:EOT STOP(stop mode at end of tape)BOT STANDBY OFF(standby mode at beginning of tape)O In the T&S&R mode, one of the following errordisplays appears on the third line (line with theamount of remaining tape).[FAN STOP]:This appears when the cooling fan has stopped.When this happens, “E-10” and the counter valueappear alternately on the front panel’s counterdisplay area.[NO RF]:This appears when a blank section has beendetected on the tape.“E-09” appears on the front panel’s counterdisplay area.[SERVO NOT LOCKED]:This appears when the servo is not locked.“E-00” appears on the front panel’s counterdisplay area.[LOW RF]:This appears when there is no head output.“E-01” appears on the front panel’s counterdisplay area.[HIGH ERROR RATE]:This appears when the error rate hasdeteriorated (when the channel conditionappears in red).“E-02” appears on the front panel’s counterdisplay area.Operation modesThe details to be displayed on the screen can beselected by setting setup menu item No.003“DISPLAY SEL.” (See page 29)“TIME”: Counter value“T&STA”: Counter value, VTR operation mode“T&R”: Counter value, amount of remaining tape“T&S&R”: Counter value, VTR operation mode,amount of remaining tapeSuperimposed ScreensCounter valueTIME modeTCR : : :TV monitorCounter valueT&STA modeTCR : : :STOPTV monitorVTR operation modeCounter valueT&S&R modeTCR : : :STOPREMAIN MINTV monitorVTR operation modeCounter valueT&R modeTCR : : :REMAIN MINTV monitorAmount of remaining tapeAmount of remaining tape