LRI4E / HRI4E Direct Vent Gas Insert | 47|47maintenanceFAN MAINTENANCE - WITH GTMF REMOTE CONTROL3. Remove fan and fan access panel from unit.4. Remove fan from back access panel by removing 3 screws from theoutside of fan access panel.5. To install - reverse steps.2. Disconnect the fan wire harness through the rear panel. Disconnect 2 x1/4" spade connectors to the fan terminals. Disconnect the ground lug tothe fan using the screw provided.FanFan Mounting BracketStrain ReliefFan Wire HarnessGround WireFan TerminalsPower CordFan ControllerWire RetainerWARNINGElectrical Grounding InstructionsThis appliance is equipped with a three-prong(grounding) plug for your protection against shockhazard and should be plugged directly into a properlygrounded three-prong receptacle. Do not cut or remove thegrounding prong from this plug.Diagram 3Diagram 2Before you begin:Shut off the gas supply to the unit.Disconnect all electrical supply to the unit.Always let the appliance cool to room temperature before servicing.Note: To access the side and rear access panels both the gas and ventingwill need to be disconnected(see vent/flue installation in this manual)for proper removal.There is no access to the blower from the front of this appliance.1. Remove 7 screws and loosen 4 screws along the bottom to remove fanaccess panel -see Diagram 1aRemove 4 screws to remove side access panel - see Diagram 1bDiagram 1bDiagram 1a= Remove= Loosen