User guide The Menu54Data format (Format) This parameter serves to define the number of data bits, the paritycheck for received data bytes and the number of stop bits per databyte.Press Format (3) key.Use the < (2) or > (3) key to select the desired setting.Setting Options: see table belowDefault Setting: 8 Bit No 1 Stop1 Sets the number of data bits: You can select 7 or 8.2 The parity test for received data bytes can be selected. NO cau-ses transmission in both directions without parity bit. If EVEN orODD is selected, the bytes are checked if they have even or oddparity. The selection of MARK or SPACE causes a data bytetransmission with parity bit, but without checking the received da-ta. Transmission data with parity bit is always marked with 1(MARK) or 0 (SPACE).3 Selects one or two stop bits per data byte.Confirm the setting by pressing the Set key (1). Press the Next key(4) to access the next group of parameters.Baud FormatOnlineSetup21 3 4Back Next8bit No 1Stop*OnlineSetupSet < > Exit21 3 41 number of data bits 2 parity test 3 number of stop bits8 Bit No 1 Stop8 Bit No 2 Stop8 Bit Even 1 Stop8 Bit Odd 1 Stop8 Bit Mark 1 Stop8 Bit Spc 1 Stop7 Bit No 2 Stop7 Bit Even 1 Stop7 Bit Odd 1 Stop7 Bit Even 2 Stop7 Bit Odd 2 Stop7 Bit Mark 1 Stop7 Bit Spc 1 Stop7 Bit Mark 2 Stop7 Bit Spc 2 Stop