Engineer programming via the keypad 16X-BUS123Vanderbilt Installation & Configuration Manual A6V1027695901.05.2016Keypress Range is 0 – 7 (Max volume)Voice Annunciation Select speaker volume for chime or disable sound.Partset Buzzer Range is 0 – 7 (Max volume)DeactivationCalendar Select if the keypad should be limited by calendar. See Calendar.Mapping gate Select if keypad should be limited by a mapping gate.Keyswitch Select if keypad should be limited by a keyswitch.PACE Entry Tick this box to disable the keys on the keypad during the entry timewhen a PACE is configured on the keypad.AreasLocation Select the secured area where the keypad is located.Areas Select which areas can be controlled through keypad.OptionsDelay Fullset Select to configure a delayed set across all keypads. The location ofthe keypad is ignored and all areas will perform a full exit time countdown.NOTICEAn area should be assigned to a keypad only if the keypad is inside the assignedarea, and if an entry/exit route is defined. If an area is assigned, when theparticular area is set or unset then entry and exit timers are used (if configured).Other features related to entry/exit routes also become available. If no area isassigned, the area is set or unset immediately and other entry/exit features arenot available.16.6.4.4 Edit ExpandersTo edit expanders:1. Scroll to EXPANDERS > EDIT.2. Press SELECT.3. Scroll to the device to be edited and press SELECT. Parameters and details, if applicable, are displayed for editing.4. Press BACK to exit the menu.For naming and identifying, expanders are allocated zones (in groupings of 8)with subsequent identities of 1 to 512. (The greatest number in zone identificationis 512.) Therefore, any expander named or identified by a number greater than 63has no allocated zones.